Packet Power Environmental Monitoring Solutions

Battery or AC power? One reading per row or 12 readings per rack? No problem. Packet Power’s range of wireless environmental monitors combines industry-leading flexibility with exceptionally low costs. Track temperature, relative humidity and differential pressure where needed. And installation is fast and easy.

Industry-leading Wireless Monitoring

Packet Power make the data center industry’s most widely used wireless power and environmental monitoring system. If you run a critical facility Packet Power products are simple to install, configure and manage, making it easier and less expensive for you to get the information you need to lower costs, avoid outages and improve operational effectiveness.

Operations Management

Utilize monitoring data to increase availability, minimize unused power and spot hot spots before they become a problem.

Energy Cost Allocation

Now that the cost to power a server over its useful life often exceeds its purchase cost, allocating operating costs is more important than ever.

Colo Companies

For companies that run data centers as their primary business, energy usage information powers decisions in many areas.

Cooling Optimization

In many facilities, gathering the data needed to more efficiently remove heat is the key to saving the most energy.

Data Center Retrofits

Increasing power densities can create both power and cooling challenges in existing data centers. Adding monitoring provides the insight needed to prevent issues and extend the life of the facility.

 

Measure PUE

Love it or hate it, PUE is one of the data center industry’s key performance metrics. Analyzing your power usage effectiveness doesn’t have to be hard.

True plug and play power monitoring

Smart Power Cable

Smart Power Cables revolutionize branch circuit monitoring. Other solutions can be costly to implement, complex to install and difficult to scale. Smart Power Cables avoid these issues by incorporating metering in a power cord and accessing the energy usage data via a wireless network. Since the cables can be used with any device with a plug, there’s no need to uninstall existing equipment, and you can have one monitoring system that works across all your devices.

Smart Power Cables support the full range of IEC, NEMA, specialized and regional connectors. There are more than 50 standard models, and custom cables can be made on request.

  • S Cable – Single­-phase circuits from 10A to 32A
  • R Cable – Single­ and three­-phase circuits from 16A to 100A
 
 

Features

  • Captures information on voltage (V), current (A), power (W), power factor, energy (Wh), frequency (Hz) and temperature
  • Maintains key data during power disruptions
  • 10 to 100 amp capacity, single- and three-phase versions, 100 to 480V
  • Local LED display
  • Supports all IEC, NEMA, regional and specialized plug and connector formats
  • Proven with thousands of cables in use worldwide
  • Fail­safe design will not disrupt the flow of power

Benefits

  • Accurately captures energy information in real-time
  • Use with any BMS or DCIM application that supports standard SNMP orModbus protocols
  • Monitors anything with a plug including SANs, mainframes and switches
  • Secure, proven wireless network designed for data centers
  • Simple ‘‘plug and play’’ installation means no electricians required
  • Highly cost­-effective
  • Self-­forming, self­-optimizing network minimizes IT resource requirements
Temperature Monitoring that Adapts to Your Needs

Environmental Monitoring Flexibility

Battery or AC power? One reading per row or 12 readings per rack? No problem. Packet Power’s range of wireless environmental monitors combines industry-leading flexibility with exceptionally low costs. Track temperature, relative humidity and differential pressure where needed. And installation is fast and easy.

Key Features:

  • Monitors temperature, humidity and differential pressure
  • Uses AC or battery power
  • Measure up to 12 temperature points per monitor
  • Utilizes Packet Power’s proven wireless mesh network
  • Each monitor covers 1 to 6 cabinets based on your needs
  • Use with EMX Energy Portal to see real­time 3D facility heat maps
  • Scales to thousands of monitoring points per facility
  • Easy integration with third party BMS and DCIM systems
  • Low cost per monitoring point
  • Leak detector probe senses the presence of water

Environmental Monitor Models

  • E300

    • 1 temperature point
    • No external probe ports
    • Dew point and relative humidity included
    • Battery powered
  • E302

    • Up to 3 temperature points
    • Two external probe ports
    • Dew point and relative humidity included
    • Battery powered
  • E306

    • Up to 6 temperature points
    • Six external probe ports
    • Dew point and relative humidity optional
    • Differential pressure optional
    • Local display
    • AC powered (or PoE splitter)
  • E312

    • Up to 12 temperature points
    • Twelve external probe ports
    • Dew point and relative humidity optional
    • Battery powered (or AC)
    •  
  • Individual Temperature Probes

    • Buy exactly what you need
    • 1 to 15 meter lengths
    • Any quantity
    • Use with E302, E306 or E312
  • Leak Detector Probe

    • Sensing height can be adjusted to as low as 1/32 of an inch (1mm)
    • 2 to 15 meter lengths
    • Any quantity
    • Use with E302, E306 or E312

Branch Circuit Monitoring

Whether you want to allocate energy costs, avoid unplanned outages or balance loads across phases, our wireless panel monitoring solutions give you the flexibility you need to measure what matters.

Packet Power’s wireless branch circuit monitors install in a fraction of the time versus other systems by eliminating communication wiring, configuration and providing fully pre-configured wiring harnesses. You’ll be online receiving useful monitoring information immediately after installation.

A significant part of the branch circuit monitoring installation involves defining the circuit mix on a particular panel and making that information usable in your monitoring application.

Our panel editor makes it easy to specify the amperage and number of poles per circuit. If you have panels with similar circuit maps, you can easily apply panel definitions from one panel to another. And if you need to access data via SNMP or Modbus, we make that easy too.

Features

  • Power versions measure V, A, VA, W, PF, Wh, THDi, THDv, Hz
  • Works with PDUs, RPPs or panelboards from any vendor
  • Monitors 100 to 480V circuits
  • Can be wall-mounted, directly attached or installed under the floor
  • Includes pre-wired, pre-configured split-core CTs in a flexible wire harness
  • Local LED displays V, A and W on main input circuit and A on branch circuits

Benefits

  • Cost effective
  • No communications cables or configuration
  • Simple, non­-technical installation
  • Use anywhere including branch circuits, RPPs, panelboards and PDUs
  • Compatible with any existing hardware and data is accessible via SNMP or Modbus
  • Secure purpose-built wireless protocol proven in data centers worldwide

Benefits

 
  • Robust: Custom­-developed a wireless networking protocol specifically to meet the demands of data centers. By keeping transmissions short, tuning the network only for monitoring, optimizing network routing with each transmission, automatically adjusting to changes on the fly, and utilizing radio frequencies best suited to difficult radio environments.
  • Simple: Wireless monitoring units install quickly and automatically create a stable wireless mesh network. As monitoring units are added and removed over time, the network immediately adapts. No other solution installs faster and is easier to manage. EMX monitoring application will have you realizing value from your data before the consultants from other DCIM vendors can hold their installation planning meetings.
  • Scalable: Growing from 50 to 1,500 monitoring points? No problem, the Packet Power network is designed to make it easy to grow over time. There is no need to buy monitoring equipment before you really need it. As the size of your monitoring network grows, simply add another Ethernet Gateway and the network will automatically rebalance traffic flow. Firmware upgrades can be done on even the largest networks via the wireless network without disruption to normal operations.
  • Secure: Packet Power separates your monitoring network from your core data networks. It provides a wireless environment that is not built on a standard protocol, uses atypical radio frequencies, is limited in scope solely to monitoring, and can’t be used as an intrusion point to your wired networks. Add 128­bit AES encryption and the option to radio isolate different portions of the wireless network from each other, and you have the most secure monitoring solution available.
  • Open: Our monitoring devices can be used with any DCIM or BMS application that supports Modbus or SNMP. Or use our EMX software to gather data from both our and other vendors monitoring units. We want to make it easy to add intelligence to your existing infrastructure.
Get in Touch

Contact us for Pricing